ES F16F-J4000-R
The FC-to-FC (4Gbps) SBOD (Switched Bunch of Drives) is designed for drive expansion with the FF or F16F RAID enclosures. The loop switched architecture improves drive loop performance across Fibre Channel dual-loops.
- Highlights
- Specifications
- Accessories
- Expansion enclosure for Fibre-to-Fibre RAID systems
- Controllers with loop switches dynamically distribute data to individual disks
- Highest density, 16 drives in 3U rack space
- Redundant SBOD controllers
- Fault-tolerant dual-loop connectivity
- Two (2) 4G FC ports per controller
- Diagnostics LED panel
- Proprietary enclosure service via in-band connections with the managing RAID enclosure
Host-to-Drive Interface | SBOD Model | Corresponding RAID Subsystem(s) | Configuration | Form Factor | |
---|---|---|---|---|---|
Model | Max. Connection | ||||
4G FC to 4G FC | F16F-J4000-R |
FF-R4030 FF-S4030 |
7 + 7 SBODs | Redundant loop-switched controllers | 3U rack- mount |
F16F-R4031-4 F16F-S4031-4 |
6 SBODs | ||||
F16F-R4031-6 F16F-S4031-6 |
6 +7 SBODs |
Host Interface
- Two (2) 4G FC ports per controller
- SES enclosure service via in-band methodology
Drive Interface
- Sixteen (16) hot swappable 4G FC disk drives
System Components
- Redundant SBOD controller configurations
- Fault-tolerant modules interfaced through a common backplane
- Redundant, hot swappable 530W power supply units
- Redundant, dual-speed cooling modules
- LED diagnostic panel
- Easy-to-use rotary ID switch to set AL_PA
Management
- Management of multiple enclosures via RAID firmware and/or through GUI
- Module status LED indicators:
- Six (6) on LED panel (1 service LED and 5 status LEDs)
- Two (2) per drive tray
- Three (3) per controller module (1 Ready/Failed LED and two (2) Link status LEDs)
- One (1) per power supply unit
- Two (2) per cooling module
Physical / Electrical
Interface
- Host Interface: Two (2) SPF ports per SBOD controller.
- Drive Interface: 4G FC
Power Supply Module
Power Requirements | |
---|---|
Input Voltage |
100VAC @ 9A 240VAC @ 4.5A with PFC (auto-switching) |
Frequency | 47 to 63Hz |
Power Consumption | 530W |
Cooling Module
Specifications | |
---|---|
Speed | High or low rotation speed controlled by firmware proactive mechanisms |
Max. Airflow (each module) |
High speed: 90CFM Low speed: 70.7CFM |
Environmental Specifications
Humidity |
|
---|---|
Temperature |
|
Altitude |
|
Dimensions
Dimensions |
With Forearm Handles (Not including rear-end protrusions) |
Without Forearm Handles |
---|---|---|
Height | 131mm (5.2 inches) | 130mm (5.1 inches) |
Width | 482.6mm (19 inches) | 445mm (17.5 inches) |
Length | 504.3mm (19.8 inches) | 488.2mm (19.2 inches) |
System weight
- Net Weight: 33kg (72.6 pounds)
- Gross Weight: 35kg (77 pounds)
Spare Parts
IFT-9273F4JIO2 | 4G-FC to 4G-FC SES SBOD controller module, 2 FC ports | |
---|---|---|
IFT-9373CDTray | 3.5" Hard disk drive tray | |
IFT-9273ECPSU | Power supply module for EonStor 3U series, ASIC400 series subsystems, 530W capacity | |
IFT-9273ECFanMod | Cooling fan module for EonStor, ASIC400, and 3U-profile series subsystems |
Accessories
IFT-9270CSFP4GA01 | Agilent Fibre Channel 4.25/2.125/1.0625 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode | |
---|---|---|
IFT-9270CFCCab01 | Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mmx2, 1 Meter | |
IFT-9270CFCCab02 | Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mmx2, 5 Meters | |
IFT-9270CFCCab03 | Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mmx2, 10 Meters | |
IFT-9273CSlider32 | Slide rail assembly, for Enhanced ES 3U/16-bay subsystem, 23"~32" rack depth | |
IFT-9273CSlider36 | Slide rail assembly, for Enhanced ES 3U/16-bay subsystem, 23"~36" rack depth |